| Type (product code) | 
			RPDE2020-□ | 
			RPDE2045-□ | 
			RPDE2060-□ | 
			RPDE2100-□ | 
		
		
			
| Input | 
			Main circuit / control circuit | 
			Rated input voltage | 
			Single-phase 100 to 240 V AC 50 Hz/60 Hz (auto identification) | 
		
		
			
| Control circuit | 
			Input capacity | 
			15 VA or less | 
		
		
			
| Output | 
			Rated current (at ambient temperature 40°C) [A] | 
			20 | 
			45 | 
			60 | 
			100 | 
		
		
			
| Cooling system | 
			Self-cooled | 
		
		
			
| Applied load | 
			Resistive load, inductive load, transformer primary control, 
			rectifier primary control (For cycle control, resistive load (alloy) only) | 
		
		
			
| Minimum load current | 
			0.5 A(However, at 100% output at the rated input voltage) | 
		
		
			
| Generated loss (at rated current) [W] | 
			30 | 
			55 | 
			70 | 
			110 | 
		
		
			
| Control | 
			Waveform control method | 
			Single-phase thyristor anti-parallel connection 
			Phase control / cycle control (intermittent) / phase angle proportion control | 
		
		
			
| Output voltage adjustment range | 
			0 to 100% (RMS value) of the main circuit power supply voltage 
			(excluding thyristor voltage drop portion) | 
		
		
			
| Input-output characteristics | 
			Linear characteristic of RMS value, linearity : ±5% FS or less (phase control) 
			Linearity: ±5% FS or less (cycle control) 
			(However, at resistive load / setting signal 10 to 90%) | 
		
		
			
| Setting signal | 
			①Manual setting 
			②Auto setting 4 to 20 mA DC, 0 to 5 V DC,1 to 5 V DC, SSC(0 /12 V) 
			③Digital setting (Front key input) | 
		
		
			
Feedback control method 
			(Phase control only) | 
			AC CLR (Types with control method A) 
			AC ACR + AC CLR (Types with control method B) (prioritizes AC CLR) | 
		
		
			
| Settable items | 
			Gradient setting, base load setting, soft start and up/down time, and auto/manual switching | 
		
		
			
Communication 
			(Note 1) | 
			Parallel run master/slave | 
			Maximum number of connectible units: 50 Main unit’ s option type “ZAP” 
			(Not compatible with the APR-N Series) | 
		
		
			
| Network communication | 
			RS-485 compliant Two-wire system Half duplex start-stop synchronization Protocol: Modbus RTU compliant Maximum number of connectible units: 31 Main unit’ s option type “ZAM” | 
		
		
			
| Error detection and protection | 
			CPU memory error, power supply error(outside power supply frequency range), auto setting input not connected, manual setting input not connected, gradient setting input not connected, reverse phase detection, data writing/reading error, thyristor abnormality, 
			heater disconnection, current limit detection, 
			communication error (option), alarm contact output | 
		
		
			
| Environment | 
			Ambient temperature | 
			-10 to +55°C 
			(reduces load current to the rated current value when the temperature is between +40°C and +55°C) | 
		
		
			
| Storage temperature | 
			-20 to +60°C | 
		
		
			
| Ambient humidity | 
			+5 to +95% RH (no condensation) | 
		
		
			
| Others | 
			No corrosive gases, dust, substances and actions that promote insulation deterioration, or vibration. Use indoors at an altitude of 1000 m or less | 
		
		
			
| Insulation | 
			Dielectric strength (main circuit to ground) | 
			2,000 V AC for 1 minute | 
		
		
			
| Insulation resistance (to ground) | 
			10 MΩ or higher, measured with 500 V DC megger tester |